1. Resources
  2. Citations Library

Citation Details

You are viewing citation details. You can save or export citation(s) below, access an article, or start a new search.

221–230 of 499 records found matching your query:
Back to Search
Select All  |  Deselect All

Headers act as filters

  •  
  • Records
      1. Author :
        Kuklin, Nelly A; Pancari, Gregory D; Tobery, Timothy W; Cope, Leslie; Jackson, Jesse; Gill, Charles; Overbye, Karen; Francis, Kevin P; Yu, Jun; Montgomery, Donna; Anderson, Annaliesa S; McClements, William; Jansen, Kathrin U
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2003
      5. Publication :
        Antimicrobial agents and chemotherapy
      6. Products :
      7. Volume :
        47
      8. Issue :
        9
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        Abscess; Acetamides; Animals; Anti-Bacterial Agents; Bioware; Catheterization; Colony Count, Microbial; Dose-Response Relationship, Drug; Female; Foreign Bodies; Luminescent Measurements; Mice; Mice, Inbred BALB C; Muscle, Skeletal; Oxazolidinones; Staphylococcal Infections; Staphylococcus aureus; Thigh; Time Factors; Wound Infection; Xen8.1
      12. Abstract :
        Staphylococcal infections associated with catheter and prosthetic implants are difficult to eradicate and often lead to chronic infections. Development of novel antibacterial therapies requires simple, reliable, and relevant models for infection. Using bioluminescent Staphylococcus aureus, we have adapted the existing foreign-body and deep-wound mouse models of staphylococcal infection to allow real-time monitoring of the bacterial colonization of catheters or tissues. This approach also enables kinetic measurements of bacterial growth and clearance in each infected animal. Persistence of infection was observed throughout the course of the study until termination of the experiment at day 16 in a deep-wound model and day 21 in the foreign-body model, providing sufficient time to test the effects of antibacterial compounds. The usefulness of both animal models was assessed by using linezolid as a test compound and comparing bioluminescent measurements to bacterial counts. In the foreign-body model, a three-dose antibiotic regimen (2, 5, and 24 h after infection) resulted in a decrease in both luminescence and bacterial counts recovered from the implant compared to those of the mock-treated infected mice. In addition, linezolid treatment prevented the formation of subcutaneous abscesses, although it did not completely resolve the infection. In the thigh model, the same treatment regimen resulted in complete resolution of the luminescent signal, which correlated with clearance of the bacteria from the thighs.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/12936968
      14. Call Number :
        PKI @ catherine.lautenschlager @
      15. Serial :
        9992
      1. Author :
        Zeng, Q.; Yang, Z.; Gao, Y. J.; Yuan, H.; Cui, K.; Shi, Y.; Wang, H.; Huang, X.; Wong, S. T.; Wang, Y.; Kesari, S.; Ji, R. R.; Xu, X.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2010
      5. Publication :
        Eur J Cancer
      6. Products :
      7. Volume :
        46
      8. Issue :
        N/A
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        MDA-MB-231-D3H2Ln, IVIS, Bioluminescence, Animals; Antineoplastic Combined Chemotherapy Protocols/*therapeutic use; Cell Hypoxia/physiology; Cell Line, Tumor; Cyclophosphamide/*therapeutic use; Female; Immunohistochemistry; Lung Neoplasms/prevention & control/secondary; Mammary Neoplasms, Experimental/*drug therapy/genetics/pathology; Mice; Mice, Nude; Sirolimus/*therapeutic use; Tumor Burden; Xenograft Model Antitumor Assays
      12. Abstract :
        Rapamycin, a mammalian target of rapamycin (mTOR) inhibitor, has been shown to inhibit the growth of oestrogen positive breast cancer. However, triple-negative (TN) breast cancer is resistant to rapamycin treatment in vitro. We set to test a combination treatment of rapamycin with DNA-damage agent, cyclophosphamide, in a TN breast cancer model. By binding to and disrupting cellular DNA, cyclophosphamide kills cells via interfering with their normal functions. We assessed the responses of nude mice bearing tumour xenografts of TN MDA-MB-231 cells to the combination of rapamycin and cyclophosphamide in both orthotopic mammary and lung-metastasis models. We tracked tumour growth and metastasis by bioluminescent imaging and examined the expression of Ki67, CD34 and HIF-1alpha in tumour tissues by immunohistochemistry and apoptosis index with TUNEL assay, and found that MDA-MB-231 cells are sensitive to rapamycin therapy in orthotopic mammary, but not in lung with metastasis. Rapamycin when combined with cyclophosphamide is found to have a more significant effect in reducing tumour volume and metastasis with a much improved survival rate. Our data also show that the sensitivity of TN tumours to rapamycin is associated with the microenvironment of the tumour cells. The data indicate that in a relatively hypoxic environment HIF-1alpha may play a role in mediating the anti-cancer effect of rapamycin and cyclophosphamide may prevent the feedback activation of Akt by rapamycin. Overall our results show that rapamycin plus cyclophosphamide can achieve an improved efficacy in suppressing tumour growth and metastasis, suggesting that the combination therapy can be a promising treatment option for TN cancer.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/20156674
      14. Call Number :
        PKI @ kd.modi @ 2
      15. Serial :
        10414
      1. Author :
        McCann CM, Waterman P, Figueiredo JL, Aikawa E, Weissleder R and Chen JW
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2009
      5. Publication :
        Neuroimage
      6. Products :
      7. Volume :
        45
      8. Issue :
        2
      9. Page Numbers :
        N/A
      10. Research Area :
        Neuroscience
      11. Keywords :
        FMT; in vivo imaging; ProSense
      12. Abstract :
        Fluorescent molecular tomographic (FMT) imaging can noninvasively monitor molecular function in living animals using specific fluorescent probes. However, macroscopic imaging methods such as FMT generally exhibit low anatomical details. To overcome this, we report a quantitative technique to image both structure and function by combining FMT and magnetic resonance (MR) imaging. We show that FMT-MR imaging can produce three-dimensional, multimodal images of living mouse brains allowing for serial monitoring of tumor morphology and protease activity. Combined FMT-MR tumor imaging provides a unique in vivo diagnostic parameter, protease activity concentration (PAC), which reflects histological changes in tumors and is significantly altered by systemic chemotherapy. Alterations in this diagnostic parameter are detectable early after chemotherapy and correlate with subsequent tumor growth, predicting tumor response to chemotherapy. Our results reveal that combined FMT-MR imaging of fluorescent molecular probes could be valuable for brain tumor drug development and other neurological and somatic imaging applications.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/19154791
      14. Call Number :
        PKI @ sarah.piper @
      15. Serial :
        4544
      1. Author :
        Kenneth M. Kozloff, Luisa Quinti, Somying Patntirapong, Peter V. Hauschka, Ching-Hsuan Tung, Ralph Weissleder and Umar Mahmood
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2009
      5. Publication :
        Bone
      6. Products :
      7. Volume :
        44
      8. Issue :
        2
      9. Page Numbers :
        N/A
      10. Research Area :
        Physiology
      11. Keywords :
        FMT; ProSense; OsteoSense; bone; osteoclast; cathepsin K; non-invasive imaging; molecular imaging; fluorescence; in vivo imaging
      12. Abstract :
        Osteoclasts degrade bone matrix by demineralization followed by degradation of type I collagen through secretion of the cysteine protease, cathepsin K. Current imaging modalities are insufficient for sensitive observation of osteoclast activity, and in vivo live imaging of osteoclast resorption of bone has yet to be demonstrated. Here, we describe a near-infrared fluorescence reporter probe whose activation by cathepsin K is shown in live osteoclast cells and in mouse models of development and osteoclast upregulation. Cathepsin K probe activity was monitored in live osteoclast cultures and correlates with cathepsin K gene expression. In ovariectomized mice, cathepsin K probe upregulation precedes detection of bone loss by micro-computed tomography. These results are the first to demonstrate non-invasive visualization of bone degrading enzymes in models of accelerated bone loss, and may provide a means for early diagnosis of upregulated resorption and rapid feedback on efficacy of treatment protocols prior to significant loss of bone in the patient.
      13. URL :
        http://www.thebonejournal.com/article/S8756-3282(08)00816-8/abstract
      14. Call Number :
        PKI @ sarah.piper @
      15. Serial :
        4526
      1. Author :
        Min, Jung-Joon; Nguyen, Vu H.; Gambhir, Sanjiv S.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2010
      5. Publication :
        Nuclear Medicine and Molecular Imaging
      6. Products :
      7. Volume :
        44
      8. Issue :
        1
      9. Page Numbers :
        15-24
      10. Research Area :
        N/A
      11. Keywords :
        Cancer; Cardiology; Gene delivery vector; Gene Therapy; Imaging / Radiology; Molecular Imaging; Nuclear Medicine; Oncology; Orthopedics; Xen26
      12. Abstract :
        Cancer persists as one of the most devastating diseases in the world. Problems including metastasis and tumor resistance to chemotherapy and radiotherapy have seriously limited the therapeutic effects of present clinical treatments. To overcome these limitations, cancer gene therapy has been developed over the last two decades for a broad spectrum of applications, from gene replacement and knockdown to vaccination, each with different requirements for gene delivery. So far, a number of genes and delivery vectors have been investigated, and significant progress has been made with several gene therapy modalities in clinical trials. Viral vectors and synthetic liposomes have emerged as the vehicles of choice for many applications. However, both have limitations and risks that restrict gene therapy applications, including the complexity of production, limited packaging capacity, and unfavorable immunological features. While continuing to improve these vectors, it is important to investigate other options, particularly nonviral biological agents such as bacteria, bacteriophages, and bacteria-like particles. Recently, many molecular imaging techniques for safe, repeated, and high-resolution in vivo imaging of gene expression have been employed to assess vector-mediated gene expression in living subjects. In this review, molecular imaging techniques for monitoring biological gene delivery vehicles are described, and the specific use of these methods at different steps is illustrated. Linking molecular imaging to gene therapy will eventually help to develop novel gene delivery vehicles for preclinical study and support the development of future human applications.
      13. URL :
        http://link.springer.com/article/10.1007/s13139-009-0006-3
      14. Call Number :
        PKI @ catherine.lautenschlager @
      15. Serial :
        10003
      1. Author :
        Kozloff, K. M.; Quinti, L.; Patntirapong, S.; Hauschka, P. V.; Tung, C. H.; Weissleder, R.; Mahmood, U.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2009
      5. Publication :
        Bone
      6. Products :
      7. Volume :
        44
      8. Issue :
        N/A
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        OsteoSense, IVIS Animals; Animals, Newborn; Bone Development; Bone Resorption/enzymology; Calcification, Physiologic; Cathepsin K; Cathepsins/genetics/*metabolism; Cell Survival; Cells, Cultured; Cryoultramicrotomy; Female; Femur/pathology; Fluorescence; Humans; Mice; Mice, Inbred BALB C; *Molecular Probe Techniques; Molecular Probes/metabolism; Osteoclasts/cytology/*enzymology; Ovariectomy; RNA, Messenger/genetics/metabolism; Up-Regulation
      12. Abstract :
        Osteoclasts degrade bone matrix by demineralization followed by degradation of type I collagen through secretion of the cysteine protease, cathepsin K. Current imaging modalities are insufficient for sensitive observation of osteoclast activity, and in vivo live imaging of osteoclast resorption of bone has yet to be demonstrated. Here, we describe a near-infrared fluorescence reporter probe whose activation by cathepsin K is shown in live osteoclast cells and in mouse models of development and osteoclast upregulation. Cathepsin K probe activity was monitored in live osteoclast cultures and correlates with cathepsin K gene expression. In ovariectomized mice, cathepsin K probe upregulation precedes detection of bone loss by micro-computed tomography. These results are the first to demonstrate non-invasive visualization of bone degrading enzymes in models of accelerated bone loss, and may provide a means for early diagnosis of upregulated resorption and rapid feedback on efficacy of treatment protocols prior to significant loss of bone in the patient.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/19007918
      14. Call Number :
        PKI @ kd.modi @ 1
      15. Serial :
        10466
      1. Author :
        Dai, T.; Tegos, G. P.; Zhiyentayev, T.; Mylonakis, E.; Hamblin, M. R.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2010
      5. Publication :
        Lasers Surg Med
      6. Products :
      7. Volume :
        42
      8. Issue :
        N/A
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        Xen31, Xen 31, MRSA, S. aureus, IVIS, Bioluminescence, Administration, Cutaneous; Animals; Disease Models, Animal; Female; *Methicillin-Resistant Staphylococcus aureus; Mice; Mice, Inbred BALB C; Photobleaching; *Photochemotherapy; Polyethyleneimine/administration & dosage; Porphyrins/*administration & dosage; Radiation-Sensitizing Agents/*administration & dosage; Staphylococcal Skin Infections/etiology/pathology/*therapy; Wound Infection/microbiology/pathology/*therapy
      12. Abstract :
        BACKGROUND AND OBJECTIVE: Methicillin-resistant Staphylococcus aureus (MRSA) skin infections are now known to be a common and important problem in the Unites States. The objective of this study was to investigate the efficacy of photodynamic therapy (PDT) for the treatment of MRSA infection in skin abrasion wounds using a mouse model. STUDY DESIGN/MATERIALS AND METHODS: A mouse model of skin abrasion wound infected with MRSA was developed. Bioluminescent strain of MRSA, a derivative of ATCC 33591, was used to allow the real-time monitoring of the extent of infection in mouse wounds. PDT was performed with the combination of a polyethylenimine (PEI)-ce6 photosensitizer (PS) and non-coherent red light. In vivo fluorescence imaging was carried out to evaluate the effect of photobleaching of PS during PDT. RESULTS: In vivo fluorescence imaging of conjugate PEI-ce6 applied in mice indicated the photobleaching effect of the PS during PDT. PDT induced on average 2.7 log(10) of inactivation of MRSA as judged by loss of bioluminescence in mouse skin abrasion wounds and accelerated the wound healing on average by 8.6 days in comparison to the untreated infected wounds. Photobleaching of PS in the wound was overcome by adding the PS solution in aliquots. CONCLUSION: PDT may represent an alternative approach for the treatment of MRSA skin infections.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/20077489
      14. Call Number :
        PKI @ kd.modi @ 3
      15. Serial :
        10553
      1. Author :
        Napp, J.; Mathejczyk, J.E.; Alves, F.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2011
      5. Publication :
        Pediatric Radiology
      6. Products :
      7. Volume :
        41
      8. Issue :
        2
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        AngioSense 680; Cancer; glioblastoma xenograft; mice; tumor vascularization
      12. Abstract :
        To obtain information on the occurrence and location of molecular events as well as to track target-specific probes such as antibodies or peptides, drugs or even cells non-invasively over time, optical imaging (OI) technologies are increasingly applied. Although OI strongly contributes to the advances made in preclinical research, it is so far, with the exception of optical coherence tomography (OCT), only very sparingly applied in clinical settings. Nevertheless, as OI technologies evolve and improve continuously and represent relatively inexpensive and harmful methods, their implementation as clinical tools for the assessment of children disease is increasing. This review focuses on the current preclinical and clinical applications as well as on the future potential of OI in the clinical routine. Herein, we summarize the development of different fluorescence and bioluminescence imaging techniques for microscopic and macroscopic visualization of microstructures and biological processes. In addition, we discuss advantages and limitations of optical probes with distinct mechanisms of target-detection as well as of different bioluminescent reporter systems. Particular attention has been given to the use of near-infrared (NIR) fluorescent probes enabling observation of molecular events in deeper tissue.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/21221568
      14. Call Number :
        PKI @ user @ 8559
      15. Serial :
        4796
Back to Search
Select All  |  Deselect All