1. Resources
  2. Citations Library

Citation Details

You are viewing citation details. You can save or export citation(s) below, access an article, or start a new search.

351–360 of 499 records found matching your query:
Back to Search
Select All  |  Deselect All

Headers act as filters

  •  
  • Records
      1. Author :
        David E Sosnovik, Matthias Nahrendorf and Ralph Weissleder
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2008
      5. Publication :
        Nature Reviews Cardiology
      6. Products :
      7. Volume :
        5
      8. Issue :
        2
      9. Page Numbers :
        N/A
      10. Research Area :
        Cardiovascular Research
      11. Keywords :
        in vivo imaging; fluorescence imaging, molecular imaging, MRI, myocardium, SPECT; MMPSense
      12. Abstract :
        Molecular imaging agents can be targeted to a specific receptor or protein on the cardiomyocyte surface, or to enzymes released into the interstitial space, such as cathepsins, matrix metalloproteinases and myeloperoxidase. Molecular imaging of the myocardium, however, requires the imaging agent to be small, sensitive (nanomolar levels or better), and able to gain access to the interstitial space. Several novel agents that fulfill these criteria have been used for targeted molecular imaging applications in the myocardium. Magnetic resonance, fluorescence, and single-photon emission CT have been used to image the molecular signals generated by these agents. The use of targeted imaging agents in the myocardium has the potential to provide valuable insights into the pathophysiology of myocardial injury and to facilitate the development of novel therapeutic strategies.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2597275/?tool=pubmed
      14. Call Number :
        PKI @ sarah.piper @
      15. Serial :
        4650
      1. Author :
        Napp, J.; Mathejczyk, J.E.; Alves, F.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2011
      5. Publication :
        Pediatric Radiology
      6. Products :
      7. Volume :
        41
      8. Issue :
        2
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        AngioSense 680; Cancer; glioblastoma xenograft; mice; tumor vascularization
      12. Abstract :
        To obtain information on the occurrence and location of molecular events as well as to track target-specific probes such as antibodies or peptides, drugs or even cells non-invasively over time, optical imaging (OI) technologies are increasingly applied. Although OI strongly contributes to the advances made in preclinical research, it is so far, with the exception of optical coherence tomography (OCT), only very sparingly applied in clinical settings. Nevertheless, as OI technologies evolve and improve continuously and represent relatively inexpensive and harmful methods, their implementation as clinical tools for the assessment of children disease is increasing. This review focuses on the current preclinical and clinical applications as well as on the future potential of OI in the clinical routine. Herein, we summarize the development of different fluorescence and bioluminescence imaging techniques for microscopic and macroscopic visualization of microstructures and biological processes. In addition, we discuss advantages and limitations of optical probes with distinct mechanisms of target-detection as well as of different bioluminescent reporter systems. Particular attention has been given to the use of near-infrared (NIR) fluorescent probes enabling observation of molecular events in deeper tissue.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/21221568
      14. Call Number :
        PKI @ user @ 8559
      15. Serial :
        4796
      1. Author :
        Goergen, C.J.; Azuma, J.; Barr, K.N.; Magdefessel, L.; Kallop, D.Y.; Gogineni, A.; Grewall, A.; Weimer, R.M.; Connolly, A.J.; Dalman, R.L.; Taylor, C.A.; Tsao, P.S.; Greve, J.M.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2011
      5. Publication :
        Arteriosclerosis, Thrombosis, and Vascular Biology
      6. Products :
      7. Volume :
        31
      8. Issue :
        2
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        Aaa; abdominal aortic aneurysm; FX Pro Kodak molecular Imaging System; ImageJ software; in vivo imaging; jugular vein injection; mice; MMPSense 680; ProSense 750; tail vein injection; thoracic aorta; vascular
      12. Abstract :
        <AbstractText Label=“OBJECTIVE” NlmCategory=“OBJECTIVE”>To quantitatively compare aortic curvature and motion with resulting aneurysm location, direction of expansion, and pathophysiological features in experimental abdominal aortic aneurysms (AAAs).</AbstractText> <AbstractText Label=“METHODS AND RESULTS” NlmCategory=“RESULTS”>MRI was performed at 4.7 T with the following parameters: (1) 3D acquisition for vessel geometry and (2) 2D cardiac-gated acquisition to quantify luminal motion. Male 24-week-old mice were imaged before and after AAA formation induced by angiotensin II (AngII)-filled osmotic pump implantation or infusion of elastase. AngII-induced AAAs formed near the location of maximum abdominal aortic curvature, and the leftward direction of expansion was correlated with the direction of suprarenal aortic motion. Elastase-induced AAAs formed in a region of low vessel curvature and had no repeatable direction of expansion. AngII significantly increased mean blood pressure (22.7 mm Hg, P<0.05), whereas both models showed a significant 2-fold decrease in aortic cyclic strain (P<0.05). Differences in patterns of elastin degradation and localization of fluorescent signal from protease-activated probes were also observed.</AbstractText> <AbstractText Label=“CONCLUSIONS” NlmCategory=“CONCLUSIONS”>The direction of AngII aneurysm expansion correlated with the direction of motion, medial elastin dissection, and adventitial remodeling. Anterior infrarenal aortic motion correlated with medial elastin degradation in elastase-induced aneurysms. Results from both models suggest a relationship between aneurysm pathological features and aortic geometry and motion.</AbstractText>
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/21071686
      14. Call Number :
        PKI @ user @ 8450
      15. Serial :
        4803
      1. Author :
        Goldberg, M.S.; Xing, D.; Ren, Y.; Orsulic, S.; Bhatia, S.N.; Sharp, P.A.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2011
      5. Publication :
        Proceedings of the National Academy of Sciences of the United States of America
      6. Products :
      7. Volume :
        108
      8. Issue :
        2
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        brca1; Cancer; In vivo imaging (VisEn); IVIS Spectrum imaging system; mice; siRNA; vivotag-750
      12. Abstract :
        Inhibition of the DNA repair enzyme poly(ADP-ribose) polymerase 1 (PARP1) with small molecules has been shown to be an effective treatment for ovarian cancer with BRCA mutations. Here, we report the in vivo administration of siRNA to Parp1 in mouse models of ovarian cancer. A unique member of the lipid-like materials known as lipidoids is shown to deliver siRNA to disseminated murine ovarian carcinoma allograft tumors following intraperitoneal (i.p.) injection. siParp1 inhibits cell growth, primarily by induction of apoptosis, in Brca1-deficient cells both in vitro and in vivo. Additionally, the treatment extends the survival of mice bearing tumors derived from Brca1-deficient ovarian cancer cells but not from Brca1 wild-type cells, confirming the proposed mechanism of synthetic lethality. Because there are 17 members of the Parp family, the inherent complementarity of RNA affords a high level of specificity for therapeutically addressing Parp1 in the context of impaired homologous recombination.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/21187397
      14. Call Number :
        PKI @ user @ 8448
      15. Serial :
        4805
      1. Author :
        Kim, Jae-Beom; Urban, Konnie; Cochran, Edward; Lee, Steve; Ang, Angel; Rice, Bradley; Bata, Adam; Campbell, Kenneth; Coffee, Richard; Gorodinsky, Alex; Lu, Zhan; Zhou, He; Kishimoto, Takashi Kei; Lassota, Peter
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2010
      5. Publication :
        PloS one
      6. Products :
      7. Volume :
        5
      8. Issue :
        2
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        4T1-luc2; Animals; Bicuculline; Bioware; Cell Line, Tumor; Diagnostic Imaging; Female; Genetic Vectors; Lentivirus; Luciferases; Luminescent Measurements; Lung Neoplasms; Mammary Neoplasms, Experimental; Mice; Mice, Inbred BALB C; Mice, Nude; Neoplasm Transplantation; Neoplasms; Sensitivity and Specificity; Time Factors; Transfection; Tumor Burden
      12. Abstract :
        Early detection of tumors can significantly improve the outcome of tumor treatment. One of the most frequently asked questions in cancer imaging is how many cells can be detected non-invasively in a live animal. Although many factors limit such detection, increasing the light emission from cells is one of the most effective ways of overcoming these limitations. Here, we describe development and utilization of a lentiviral vector containing enhanced firefly luciferase (luc2) gene. The resulting single cell clones of the mouse mammary gland tumor (4T1-luc2) showed stable light emission in the range of 10,000 photons/sec/cell. In some cases individual 4T1-luc2 cells inserted under the skin of a nu/nu mouse could be detected non-invasively using a cooled CCD camera in some cases. In addition, we showed that only few cells are needed to develop tumors in these mice and tumor progression can be monitored right after the cells are implanted. Significantly higher luciferase activity in these cells allowed us to detect micrometastases in both, syngeneic Balb/c and nu/nu mice.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/20186331
      14. Call Number :
        PKI @ catherine.lautenschlager @
      15. Serial :
        8938
      1. Author :
        Thobe, M N; Gurusamy, D; Pathrose, P; Waltz, S E
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2010
      5. Publication :
        Oncogene
      6. Products :
      7. Volume :
        29
      8. Issue :
        2
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        Animals; Antigens, CD31; Bioware; Blotting, Western; Cell Line; Cell Line, Tumor; Cell Movement; Chemokine CXCL1; Chemokine CXCL5; Chemokines; Endothelial Cells; Gene Expression Regulation, Neoplastic; Humans; Immunohistochemistry; Interleukin-8; Male; Mice; Mice, Nude; Neoplasms, Experimental; Neovascularization, Pathologic; NF-kappa B; PC-3M-luc2; Prostatic Neoplasms; Receptor Protein-Tyrosine Kinases; Reverse Transcriptase Polymerase Chain Reaction; RNA Interference; Transplantation, Heterologous
      12. Abstract :
        Overexpression of the Ron receptor tyrosine kinase has recently been shown in a wide variety of human cancers. However, no studies have examined Ron receptor expression or function during prostate tumorigenesis. In this study we report that Ron is highly expressed in human prostate adenocarcinoma and metastatic lymph nodes when compared with normal prostate or benign prostate hyperplasia. Furthermore, we show that Ron is overexpressed in PC-3 and DU145 prostate cancer cell lines, and that the levels of angiogenic chemokines produced by prostate cancer cells positively correlate with Ron expression. The knockdown of Ron in PC-3 or DU145 cells results in a significant decrease in angiogenic chemokine production and is associated with a decreased activation of the transcription factor nuclear factor-kappaB (NF-kappaB). Moreover, exogenous overexpression of Ron in LNCaP cells is sufficient to induce a significant increase in angiogenic chemokines that can be abrogated by inhibition of NF-kappaB signaling. Given that the function of angiogenic chemokines is important in the development of new blood vessels, we also examined the ability of Ron to modulate endothelial cell migration. Our data show that knockdown of Ron in prostate cancer cells results in significantly less endothelial cell chemotaxis when compared with Ron-expressing cells in vitro as well as in reduced tumor growth and decreased microvessel density after orthotopic transplantation into the prostate in vivo. In total, our data suggest that the Ron receptor is important in modulating prostate tumor growth by modulating angiogenic chemokine production and subsequent endothelial cell recruitment.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/19838218
      14. Call Number :
        PKI @ catherine.lautenschlager @
      15. Serial :
        8943
      1. Author :
        Kuo, Chaincy; Coquoz, Olivier; Troy, Tamara L; Xu, Heng; Rice, Brad W
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2007
      5. Publication :
        Journal of biomedical optics
      6. Products :
      7. Volume :
        12
      8. Issue :
        2
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        Animals; Bioware; Image Interpretation, Computer-Assisted; Imaging, Three-Dimensional; Luminescent Proteins; Male; Mice; Microscopy, Fluorescence, Multiphoton; PC-3M-luc; Prostatic Neoplasms; Whole Body Imaging
      12. Abstract :
        A new method is described for obtaining a 3-D reconstruction of a bioluminescent light source distribution inside a living animal subject, from multispectral images of the surface light emission acquired on charge-coupled device (CCD) camera. The method uses the 3-D surface topography of the animal, which is obtained from a structured light illumination technique. The forward model of photon transport is based on the diffusion approximation in homogeneous tissue with a local planar boundary approximation for each mesh element, allowing rapid calculation of the forward Green's function kernel. Absorption and scattering properties of tissue are measured a priori as input to the algorithm. By using multispectral images, 3-D reconstructions of luminescent sources can be derived from images acquired from only a single view. As a demonstration, the reconstruction technique is applied to determine the location and brightness of a source embedded in a homogeneous phantom subject in the shape of a mouse. The technique is then evaluated with real mouse models in which calibrated sources are implanted at known locations within living tissue. Finally, reconstructions are demonstrated in a PC3M-luc (prostate tumor line) metastatic tumor model in nude mice.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/17477722
      14. Call Number :
        PKI @ catherine.lautenschlager @
      15. Serial :
        8968
      1. Author :
        Priddle, Helen; Grabowska, Anna; Morris, Teresa; Clarke, Philip A; McKenzie, Andrew J; Sottile, Virginie; Denning, Chris; Young, Lorraine; Watson, Sue
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2009
      5. Publication :
        Cloning and stem cells
      6. Products :
      7. Volume :
        11
      8. Issue :
        2
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        Animals; Bioware; Cell Differentiation; Chick Embryo; Embryonic Stem Cells; Fluorescent Dyes; Humans; Luciferases; Luminescent Measurements; Mice; Mice, SCID; PC-3M-luc; Software; Stem Cell Transplantation; Teratoma
      12. Abstract :
        Research into the behavior, efficacy, and biosafety of stem cells with a view to clinical transplantation requires the development of noninvasive methods for in vivo imaging of cells transplanted into animal models. This is particularly relevant for human embryonic stem cells (hESCs), because transplantation of undifferentiated hESCs leads to tumor formation. The present study aimed to monitor hESCs in real time when injected in vivo. hESCs were stably transfected to express luciferase, and luciferase expression was clearly detected in the undifferentiated and differentiated state. When transfected hESCs were injected into chick embryos, bioluminescence could be detected both ex and in ovo. In the SCID mouse model, undifferentiated hESCs were detectable after injection either into the muscle layer of the peritoneum or the kidney capsule. Tumors became detectable between days 10-30, with approximately a 3 log increase in the luminescence signal by day 75. The growth phase occurred earlier in the kidney capsule and then reached a plateau, whilst tumors in the peritoneal wall grew steadily throughout the period analysed. These results show the widespread utility of bioluminescent for in vivo imaging of hESCs in a variety of model systems for preclinical research into regenerative medicine and cancer biology.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/19522673
      14. Call Number :
        PKI @ catherine.lautenschlager @
      15. Serial :
        8961
      1. Author :
        Shan, Liang; Wang, Songping; Sridhar, Rajagopalan; Bhujwalla, Zaver M; Wang, Paul C
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2007
      5. Publication :
        Molecular imaging
      6. Products :
      7. Volume :
        6
      8. Issue :
        2
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        Animals; Bioware; Breast Neoplasms; Cell Line, Tumor; Fluorescence; Fluorescent Dyes; Humans; Liposomes; Magnetic Resonance Imaging; Magnetics; MDA-MB-231-D3H1 cells; Mice; Mice, Inbred Strains; Microscopy, Confocal; Molecular Probes; Optics and Photonics; Transferrin; Xenograft Model Antitumor Assays
      12. Abstract :
        A dual probe with fluorescent and magnetic reporter groups was constructed by linkage of the near-infrared (NIR) fluorescent transferrin conjugate (Tf(NIR)) on the surface of contrast agent-encapsulated cationic liposome (Lip-CA). This probe was used for magnetic resonance imaging (MRI) and optical imaging of MDA-MB-231-luc breast cancer cells grown as a monolayer in vitro and as solid tumor xenografts in nude mice. Confocal microscopy, optical imaging, and MRI showed a dramatic increase of in vitro cellular uptake of the fluorescent and magnetic reporter groups from the probe compared with the uptake of contrast agent or Lip-CA alone. Pretreatment with transferrin (Tf) blocked uptake of the probe reporters, indicating the importance and specificity of the Tf moiety for targeting. Intravenous administration of the dual probe to nude mice significantly enhanced the tumor contrast in MRI, and preferential accumulation of the fluorescent signal was clearly seen in NIR-based optical images. More interestingly, the contrast enhancement in MRI showed a heterogeneous pattern within tumors, which reflected the tumor's morphologic heterogeneity. These results indicate that the newly developed dual probe enhances the tumor image contrast and is superior to contrast agent alone for identifying the tumor pathologic features on the basis of MRI but also is suitable for NIR-based optical imaging.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/17445503
      14. Call Number :
        PKI @ catherine.lautenschlager @
      15. Serial :
        8992
Back to Search
Select All  |  Deselect All