Home |
Headers act as filters
- Records
-
- Author
:
Sottnik, J. L.; U, L. W.'Ren; Thamm, D. H.; Withrow, S. J.; Dow, S. W. - Title
:
- Type
:
Journal Article - Year
:
2010 - Publication
:
Cancer Immunol Immunother - Products
:
- Volume
:
59 - Issue
:
N/A - Page Numbers
:
N/A - Research Area : N/A
- Keywords
:
Animals, Chronic Disease, Disease Models, Animal, Immunity, Innate, Killer Cells, Natural/immunology, Macrophages/immunology, Mice, Mice, Inbred C3H, Mice, Inbred Strains, Monocytes/immunology, Neoplasms, Neovascularization, Pathologic, Osteomyelitis/*complications, Osteosarcoma/*complications/*immunology/pathology, Staphylococcal Infections/*complications IVIS, Xenogen, Xen36 - Abstract
:
Clinical studies over the past several years have reported that metastasis-free survival times in humans and dogs with osteosarcoma are significantly increased in patients that develop chronic bacterial osteomyelitis at their surgical site. However, the immunological mechanism by which osteomyelitis may suppress tumor growth has not been investigated. Therefore, we used a mouse model of osteomyelitis to assess the effects of bone infection on innate immunity and tumor growth. A chronic Staphylococcal osteomyelitis model was established in C3H mice and the effects of infection on tumor growth of syngeneic DLM8 osteosarcoma were assessed. The effects of infection on tumor angiogenesis and innate immunity, including NK cell and monocyte responses, were assessed. We found that osteomyelitis significantly inhibited the growth of tumors in mice, and that the effect was independent of the infecting bacterial type, tumor type, or mouse strain. Depletion of NK cells or monocytes reversed the antitumor activity elicited by infection. Moreover, infected mice had a significant increase in circulating monocytes and numbers of tumor associated macrophages. Infection suppressed tumor angiogenesis but did not affect the numbers of circulating endothelial cells. Therefore, we concluded that chronic localized bacterial infection could elicit significant systemic antitumor activity dependent on NK cells and macrophages. - URL
:
http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=19701748 - Call Number
:
143227 - Serial
:
5718
- Author
-
- Author
:
Dai, T.; Tegos, G. P.; Zhiyentayev, T.; Mylonakis, E.; Hamblin, M. R. - Title
:
Photodynamic Therapy for Methicillin-Resistant Staphylococcus aureus Infection in a Mouse Skin Abrasion Model - Type
:
Journal Article - Year
:
2010 - Publication
:
Lasers in Surgery and Medicine - Products
:
- Volume
:
42 - Issue
:
N/A - Page Numbers
:
N/A - Research Area : N/A
- Keywords
:
IVIS, Xenogen, Xen30 - Abstract
:
N/A - URL
:
N/A - Call Number
:
137212 - Serial
:
7293
- Author
-
- Author
:
Pozo, J. L. del; Rouse, M. S.; Mandrekar, J. N.; Sampedro, M. F.; Steckelberg, J. M.; Patel, R. - Title
:
- Type
:
Journal Article - Year
:
2009 - Publication
:
Antimicrobial Agents and Chemotherapy - Products
:
- Volume
:
53 - Issue
:
N/A - Page Numbers
:
N/A - Research Area : N/A
- Keywords
:
IVIS, Xenogen, Xen30, Xen5, Xen41 - Abstract
:
Bacterial biofilms are resistant to conventional antimicrobial agents. Prior in vitro studies have shown that electrical current (EC) enhances the activities of aminoglycosides, quinolones, and oxytetracycline against Pseudomonas aeruginosa, Klebsiella pneumoniae, Staphylococcus epidermidis, Escherichia coli, and Streptococcus gordonii. This phenomenon, known as the bioelectric effect, has been only partially defined. The purpose of this work was to study the in vitro bioelectric effect on the activities of 11 antimicrobial agents representing a variety of different classes against P. aeruginosa, methicillin-resistant Staphylococcus aureus (MRSA), and S. epidermidis. An eight-channel current generator/controller and eight chambers delivering a continuous flow of fresh medium with or without antimicrobial agents and/or EC to biofilm-coated coupons were used. No significant decreases in the numbers of log10 CFU/cm2 were seen after exposure to antimicrobial agents alone, with the exception of a 4.57-log-unit reduction for S. epidermidis and trimethoprim-sulfamethoxazole. We detected a statistically significant bioelectric effect when vancomycin plus 2,000 microamperes EC were used against MRSA biofilms (P = 0.04) and when daptomycin and erythromycin were used in combination with 200 or 2,000 microamperes EC against S. epidermidis biofilms (P = 0.02 and 0.0004, respectively). The results of these experiments indicate that the enhancement of the activity of antimicrobial agents against biofilm organisms by EC is not a generalizable phenomenon across microorganisms and antimicrobial agents. - URL
:
http://www.ncbi.nlm.nih.gov/pubmed/18725436 - Call Number
:
137347 - Serial
:
5991
- Author
-
- Author
:
Pozo, J. L. del; Rouse, M. S.; Mandrekar, J. N.; Steckelberg, J. M.; Patel, R. - Title
:
- Type
:
Journal Article - Year
:
2009 - Publication
:
Antimicrob Agents Chemother - Products
:
- Volume
:
53 - Issue
:
N/A - Page Numbers
:
N/A - Research Area : N/A
- Keywords
:
Aza Compounds/pharmacology, Biofilms/drug effects/*growth & development, Electricity/*adverse effects, Pseudomonas/drug effects/*growth & development, Quinolines/pharmacology, Staphylococcus/drug effects/*growth & development, Tobramycin/pharmacology IVIS, Xenogen, Xen30 - Abstract
:
The activity of electrical current against planktonic bacteria has previously been demonstrated. The short-term exposure of the bacteria in biofilms to electrical current in the absence of antimicrobials has been shown to have no substantial effect; however, longer-term exposure has not been studied. A previously described in vitro model was used to determine the effect of prolonged exposure (i.e., up to 7 days) to low-intensity (i.e., 20-, 200-, and 2,000-microampere) electrical direct currents on Pseudomonas aeruginosa, Staphylococcus aureus, and Staphylococcus epidermidis biofilms. Dose- and time-dependent killing was observed. A maximum of a 6-log(10)-CFU/cm(2) reduction was observed when S. epidermidis biofilms were exposed to 2,000 microamperes for at least 2 days. A 4- to 5-log(10)-CFU/cm(2) reduction was observed when S. aureus biofilms were exposed to 2,000 microamperes for at least 2 days. Finally, a 3.5- to 5-log(10)-CFU/cm(2) reduction was observed when P. aeruginosa biofilms were exposed to electrical current for 7 days. A higher electrical current intensity correlated with greater decreases in viable bacteria at all time points studied. In conclusion, low-intensity electrical current substantially reduced the numbers of viable bacteria in staphylococcal or Pseudomonas biofilms, a phenomenon we have labeled the “electricidal effect.” - URL
:
http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=18955534 - Call Number
:
137350 - Serial
:
7845
- Author
-
- Author
:
N/A - Title
:
- Type
:
Journal Article - Year
:
2005 - Publication
:
Infection and Immunity - Products
:
- Volume
:
73 - Issue
:
N/A - Page Numbers
:
N/A - Research Area : N/A
- Keywords
:
IVIS, Xenogen, Xen31 - Abstract
:
Nasal carriage is a major risk factor for Staphylococcus aureus infection, especially for methicillin-resistant strains (MRSA). Using a mouse model of nasal carriage, we have compared several S. aureus strains and demonstrated increased colonization levels by MRSA in cystic fibrosis transmembrane conductance regulator-deficient mice and Toll-like receptor 2 (TLR2)-deficient mice but not TLR4-deficient mice. - URL
:
http://www.ncbi.nlm.nih.gov/pubmed/15731086 - Call Number
:
138154 - Serial
:
5485
- Author
-
- Author
:
Dai, T.; Tegos, G. P.; Burkatovskaya, M.; Castano, A. P.; Hamblin, M. R. - Title
:
- Type
:
Journal Article - Year
:
2009 - Publication
:
Antimicrobial Agents and Chemotherapy - Products
:
- Volume
:
53 - Issue
:
N/A - Page Numbers
:
N/A - Research Area : N/A
- Keywords
:
IVIS, Xenogen, Xen5, Xen44 - Abstract
:
An engineered chitosan acetate bandage preparation (HemCon) is used as a hemostatic dressing, and its chemical structure suggests that it should also be antimicrobial. We previously showed that when a chitosan acetate bandage was applied to full-thickness excisional wounds in mice that had been infected with pathogenic bioluminescent bacteria (Pseudomonas aeruginosa, Proteus mirabilis, and Staphylococcus aureus), it was able to rapidly kill the bacteria and save the mice from developing fatal infections. Wound healing was also stimulated. In the present study, we asked whether a chitosan acetate bandage could act as a topical antimicrobial dressing when it was applied to third-degree burns in mice contaminated with two of these bacterial species (P. aeruginosa and P. mirabilis). Preliminary experiments established the length of burn time and the number of bacteria needed to produce fatal infections in untreated mice and established that the chitosan acetate bandage could adhere to the infected burn for up to 21 days. In the case of P. aeruginosa infections, the survival rate of mice treated with the chitosan acetate bandage was 73.3% (whereas the survival rate of mice treated with a nanocrystalline silver dressing was 27.3% [P = 0.0055] and that of untreated mice was 13.3% [P < 0.0002]). For P. mirabilis infections, the comparable survival rates were 66.7%, 62.5%, and 23.1% respectively. Quantitative bioluminescent signals showed that the chitosan acetate bandage effectively controlled the growth of bacteria in the burn and prevented the development of systemic sepsis, as shown by blood culture. These data suggest that chitosan acetate bandage is efficacious in preventing fatal burn infections. - URL
:
http://www.ncbi.nlm.nih.gov/pubmed/19015341 - Call Number
:
137209 - Serial
:
5713
- Author
-
- Author
:
Sadikot, R. T.; Blackwell, T. S. - Title
:
- Type
:
Journal Article - Year
:
2008 - Publication
:
Methods Mol Biol - Products
:
- Volume
:
477 - Issue
:
N/A - Page Numbers
:
N/A - Research Area : N/A
- Keywords
:
Adenoviridae/genetics, Anesthesia, Animals, Firefly Luciferin/administration & dosage/pharmacology, *Gene Expression Regulation/drug effects, Genetic Vectors/genetics, Luciferases/metabolism, Luminescent Measurements/*methods, Mice, Photons, Whole Body Imaging/*methods IVIS, Xenogen, Xen5 - Abstract
:
Molecular imaging offers many unique opportunities to study biological processes in intact organisms. Bioluminescence is the emission of light from biochemical reactions that occur within a living organism. Luciferase has been used as a reporter gene in transgenic mice but, until bioluminescence imaging was described, the detection of luciferase activity required either sectioning of the animal or excision of tissue and homogenization to measure enzyme activities in a conventional luminometer. Bioluminescence imaging (BLI) is based on the idea that biological light sources can be incorporated into cells and animal models artificially that does not naturally express the luminescent genes. This imaging modality has proven to be a very powerful methodology to detect luciferase reporter activity in intact animal models. This form of optical imaging is low cost and noninvasive and facilitates real-time analysis of disease processes at the molecular level in living organisms. Bioluminescence provides a noninvasive method to monitor gene expression in vivo and has enormous potential to elucidate the pathobiology of lung diseases in intact mouse models, including models of inflammation/injury, infection, and cancer. - URL
:
http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=19082962 - Call Number
:
142705 - Serial
:
5558
- Author
-
- Author
:
Apidianakis, Y.; Mindrinos, M. N.; Xiao, W.; Tegos, G. P.; Papisov, M. I.; Hamblin, M. R.; Davis, R. W.; Tompkins, R. G.; Rahme, L. G. - Title
:
- Type
:
Journal Article - Year
:
2007 - Publication
:
PLoS One - Products
:
- Volume
:
2 - Issue
:
N/A - Page Numbers
:
N/A - Research Area : N/A
- Keywords
:
IVIS, Xenogen, Xen5 - Abstract
:
Despite recent advances in our understanding the pathophysiology of trauma, the basis of the predisposition of trauma patients to infection remains unclear. A Drosophila melanogaster/Pseudomonas aeruginosa injury and infection model was used to identify host genetic components that contribute to the hyper-susceptibility to infection that follows severe trauma. We show that P. aeruginosa compromises skeletal muscle gene (SMG) expression at the injury site to promote infection. We demonstrate that activation of SMG structural components is under the control of cJun-N-terminal Kinase (JNK) Kinase, Hemipterous (Hep), and activation of this pathway promotes local resistance to P. aeruginosa in flies and mice. Our study links SMG expression and function to increased susceptibility to infection, and suggests that P. aeruginosa affects SMG homeostasis locally by restricting SMG expression in injured skeletal muscle tissue. Local potentiation of these host responses, and/or inhibition of their suppression by virulent P. aeruginosa cells, could lead to novel therapies that prevent or treat deleterious and potentially fatal infections in severely injured individuals. - URL
:
http://www.ncbi.nlm.nih.gov/pubmed/18159239 - Call Number
:
135889 - Serial
:
6705
- Author
-
- Author
:
Kadurugamuwa, J. L.; Modi, K.; Yu, J.; Francis, K. P.; Purchio, T.; Contag, P. R. - Title
:
- Type
:
Journal Article - Year
:
2005 - Publication
:
Infection and Immunity - Products
:
- Volume
:
73 - Issue
:
N/A - Page Numbers
:
N/A - Research Area : N/A
- Keywords
:
Animals, Diagnostic Imaging/ methods, Female, Mice, Microscopy, Electron, Scanning, Photons, Proteus Infections/ diagnosis, Proteus mirabilis/drug effects/isolation & purification, Pseudomonas Infections/ diagnosis, Pseudomonas aeruginosa/drug effects/isolation & purification, Urinary Catheterization/ adverse effects, Urinary Tract Infections/ diagnosis IVIS, Xenogen, Xen5, Xen44 - Abstract
:
Urinary tract infections (UTIs) are among the most common bacterial infections acquired by humans, particularly in catheterized patients. A major problem with catheterization is the formation of bacterial biofilms on catheter material and the risk of developing persistent UTIs that are difficult to monitor and eradicate. To better understand the course of UTIs and allow more accurate studies of in vivo antibiotic efficacy, we developed a catheter-based biofilm infection model with mice, using bioluminescently engineered bacteria. Two important urinary tract pathogens, Pseudomonas aeruginosa and Proteus mirabilis, were made bioluminescent by stable insertion of a complete lux operon. Segments of catheter material (precolonized or postimplant infected) with either pathogen were placed transurethrally in the lumen of the bladder by using a metal stylet without surgical manipulation. The bioluminescent strains were sufficiently bright to be readily monitored from the outside of infected animals, using a low-light optical imaging system, including the ability to trace the ascending pattern of light-emitting bacteria through ureters to the kidneys. Placement of the catheter in the bladder not only resulted in the development of strong cystitis that persisted significantly longer than in mice challenged with bacterial suspensions alone but also required prolonged antibiotic treatment to reduce the level of infection. Treatment of infected mice for 4 days with ciprofloxacin at 30 mg/kg of body weight twice a day cured cystitis and renal infection in noncatheterized mice. Similarly, ciprofloxacin reduced the bacterial burden to undetectable levels in catheterized mice but did not inhibit rebound of the infection upon cessation of antibiotic therapy. This methodology easily allows spatial information to be monitored sequentially throughout the entire disease process, including ascending UTI, treatment efficacy, and relapse, all without exogenous sampling, which is not possible with conventional methods. - URL
:
http://www.ncbi.nlm.nih.gov/pubmed/15972473 - Call Number
:
139333 - Serial
:
7110
- Author
-
- Author
:
BitMansour, A.; Burns, S. M.; Traver, D.; Akashi, K.; Contag, C. H.; Weissman, I. L.; Brown, J. M. - Title
:
- Type
:
Journal Article - Year
:
2002 - Publication
:
Blood - Products
:
- Volume
:
100 - Issue
:
N/A - Page Numbers
:
N/A - Research Area : N/A
- Keywords
:
Administration, Inhalation, Animals, Animals, Congenic, Aspergillosis/microbiology/*prevention & control, *Aspergillus fumigatus, Cell Lineage, Filgrastim/pharmacology, *Hematopoietic Stem Cell Transplantation, Injections, Intraperitoneal, Luminescent Measurements, Lung Diseases, Fungal/microbiology/*prevention & control, Mice, Mice, Inbred C57BL, Myeloid Progenitor Cells/physiology/*transplantation, Neutropenia/complications/drug therapy, Pseudomonas Infections/microbiology/*prevention & control, Radiation Chimera, Research Support, Non-U.S. Gov't, Research Support, U.S. Gov't, P.H.S., Tissue Distribution IVIS, Xenogen, Xen5 - Abstract
:
Myelotoxic treatments for oncologic diseases are often complicated by neutropenia, which renders patients susceptible to potentially lethal infections. In these studies of murine hematopoietic stem cell transplantation (HSCT), cotransplantation of lineage-restricted progenitors known as common myeloid progenitors (CMP) and granulocyte-monocyte progenitors (GMP) protects against death following otherwise lethal challenge with either of 2 pathogens associated with neutropenia: Aspergillus fumigatus and Pseudomonas aeruginosa. Cotransplantation of CMP/GMP resulted in a significant and rapid increase in the absolute number of myeloid cells in the spleen, most of which were derived from the donor CMP/GMP. Despite persistent peripheral neutropenia, improved survival correlated with the measurable appearance of progenitor-derived myeloid cells in the spleen. A marked reduction or elimination of tissue pathogen load was confirmed by culture and correlated with survival. Localization of infection by P aeruginosa and extent of disease was also assessed by in vivo bioluminescent imaging using a strain of P aeruginosa engineered to constitutively express a bacterial luciferase. Imaging confirmed that transplantation with a graft containing hematopoietic stem cells and CMP/GMP reduced the bacterial load as early as 18 hours after infection. These results demonstrate that enhanced reconstitution of a tissue myeloid pool offers protection against lethal challenge with serious fungal and bacterial pathogens. - URL
:
http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=12393415 - Call Number
:
136279 - Serial
:
7031
- Author