1. Resources
  2. Citations Library

Citation Details

You are viewing citation details. You can save or export citation(s) below, access an article, or start a new search.

371–380 of 499 records found matching your query:
Back to Search
Select All  |  Deselect All

Headers act as filters

      1. Author :
        Klohs J, Baeva N, Steinbrink J, Bourayou R, Boettcher C, Royl G, Megow D, Dirnagl U, Priller J and Wunder A
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2009
      5. Publication :
        Journal of Cerebral Blood Flow and Metabolism
      6. Products :
      7. Volume :
        29
      8. Issue :
        7
      9. Page Numbers :
        N/A
      10. Research Area :
        Neuroscience
      11. Keywords :
        MMPSense; in vivo imaging; matrix metalloproteinases; stroke
      12. Abstract :
        Matrix metalloproteinases (MMPs) have been implicated in the pathophysiology of cerebral ischemia. In this study, we explored whether MMP activity can be visualized by noninvasive near-infrared fluorescence (NIRF) imaging using an MMP-activatable probe in a mouse model of stroke. C57Bl6 mice were subjected to transient middle cerebral artery occlusion (MCAO) or sham operation. Noninvasive NIRF imaging was performed 24 h after probe injection, and target-to-background ratios (TBRs) between the two hemispheres were determined. TBRs were significantly higher in MCAO mice injected with the MMP-activatable probe than in sham-operated mice and in MCAO mice that were injected with the nonactivatable probe as controls. Treatment with an MMP inhibitor resulted in significantly lower TBRs and lesion volumes compared to injection of vehicle. To test the contribution of MMP-9 to the fluorescence signal, MMP9-deficient (MMP9(-/-)) mice and wild-type controls were subjected to MCAO of different durations to attain comparable lesion volumes. TBRs were significantly lower in MMP9(-/-) mice, suggesting a substantial contribution of MMP-9 activity to the signal. Our study shows that MMP activity after cerebral ischemia can be imaged noninvasively with NIRF using an MMP-activatable probe, which might be a useful tool to study MMP activity in the pathophysiology of the disease.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/19417756
      14. Call Number :
        PKI @ sarah.piper @
      15. Serial :
        4547
      1. Author :
        McCann CM, Waterman P, Figueiredo JL, Aikawa E, Weissleder R and Chen JW
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2009
      5. Publication :
        Neuroimage
      6. Products :
      7. Volume :
        45
      8. Issue :
        2
      9. Page Numbers :
        N/A
      10. Research Area :
        Neuroscience
      11. Keywords :
        FMT; in vivo imaging; ProSense
      12. Abstract :
        Fluorescent molecular tomographic (FMT) imaging can noninvasively monitor molecular function in living animals using specific fluorescent probes. However, macroscopic imaging methods such as FMT generally exhibit low anatomical details. To overcome this, we report a quantitative technique to image both structure and function by combining FMT and magnetic resonance (MR) imaging. We show that FMT-MR imaging can produce three-dimensional, multimodal images of living mouse brains allowing for serial monitoring of tumor morphology and protease activity. Combined FMT-MR tumor imaging provides a unique in vivo diagnostic parameter, protease activity concentration (PAC), which reflects histological changes in tumors and is significantly altered by systemic chemotherapy. Alterations in this diagnostic parameter are detectable early after chemotherapy and correlate with subsequent tumor growth, predicting tumor response to chemotherapy. Our results reveal that combined FMT-MR imaging of fluorescent molecular probes could be valuable for brain tumor drug development and other neurological and somatic imaging applications.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/19154791
      14. Call Number :
        PKI @ sarah.piper @
      15. Serial :
        4544
      1. Author :
        Rahul Anil Sheth; Rabi Upadhyay; Lars Stangenberg; Rucha Sheth; Ralph Weissleder; Umar Mahmood
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2009
      5. Publication :
        Gynecologic Oncology
      6. Products :
      7. Volume :
        112
      8. Issue :
        3
      9. Page Numbers :
        N/A
      10. Research Area :
        Cancer
      11. Keywords :
        Ovarian cancer; Molecular imaging; Intraoperative imaging; Fluorescence imaging
      12. Abstract :
        OBJECTIVES: Cytoreductive surgery is a cornerstone of therapy in metastatic ovarian cancer. While conventional white light (WL) inspection detects many obvious tumor foci, careful histologic comparison has shown considerable miss rates for smaller foci. The goal of this study was to compare tumor detection using WL versus near infrared (NIR) imaging with a protease activatable probe, as well as to evaluate the ability to quantify NIR fluorescence using a novel quantitative optical imaging system.

        METHODS: A murine model for peritoneal carcinomatosis was generated and metastatic foci were imaged using WL and NIR imaging following the i.v. administration of the protease activatable probe ProSense750. The presence of tumor was confirmed by histology. Additionally, the ability to account for variations in fluorescence signal intensity due to changes in distance between the catheter and target lesion during laparoscopic procedures was evaluated.

        RESULTS: NIR imaging with a ProSense750 significantly improved upon the target-to-background ratios (TBRs) of tumor foci in comparison to WL imaging (minimum improvement was approximately 3.5 fold). Based on 52 histologically validated samples, the sensitivity for WL imaging was 69%, while the sensitivity for NIR imaging was 100%. The effects of intraoperative distance changes upon fluorescence intensity were corrected in realtime, resulting in a decrease from 89% to 5% in signal variance during fluorescence laparoscopy.

        CONCLUSIONS: With its molecular specificity, low background autofluorescence, high TBRs, and quantitative signal, optical imaging with NIR protease activatable probes greatly improves upon the intraoperative detection of ovarian cancer metastases.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/19135233?ordinalpos=1&itool=EntrezSystem2.PEntrez.Pubmed.Pubmed_ResultsPanel.Pubmed_DefaultReportPanel.Pubmed_RVDocSum
      14. Call Number :
        PKI @ sarah.piper @
      15. Serial :
        4497
      1. Author :
        Dai, T.; Tegos, G. P.; Burkatovskaya, M.; Castano, A. P.; Hamblin, M. R.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2009
      5. Publication :
        Antimicrobial Agents and Chemotherapy
      6. Products :
      7. Volume :
        53
      8. Issue :
        N/A
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        IVIS, Xenogen, Xen5, Xen44
      12. Abstract :
        An engineered chitosan acetate bandage preparation (HemCon) is used as a hemostatic dressing, and its chemical structure suggests that it should also be antimicrobial. We previously showed that when a chitosan acetate bandage was applied to full-thickness excisional wounds in mice that had been infected with pathogenic bioluminescent bacteria (Pseudomonas aeruginosa, Proteus mirabilis, and Staphylococcus aureus), it was able to rapidly kill the bacteria and save the mice from developing fatal infections. Wound healing was also stimulated. In the present study, we asked whether a chitosan acetate bandage could act as a topical antimicrobial dressing when it was applied to third-degree burns in mice contaminated with two of these bacterial species (P. aeruginosa and P. mirabilis). Preliminary experiments established the length of burn time and the number of bacteria needed to produce fatal infections in untreated mice and established that the chitosan acetate bandage could adhere to the infected burn for up to 21 days. In the case of P. aeruginosa infections, the survival rate of mice treated with the chitosan acetate bandage was 73.3% (whereas the survival rate of mice treated with a nanocrystalline silver dressing was 27.3% [P = 0.0055] and that of untreated mice was 13.3% [P < 0.0002]). For P. mirabilis infections, the comparable survival rates were 66.7%, 62.5%, and 23.1% respectively. Quantitative bioluminescent signals showed that the chitosan acetate bandage effectively controlled the growth of bacteria in the burn and prevented the development of systemic sepsis, as shown by blood culture. These data suggest that chitosan acetate bandage is efficacious in preventing fatal burn infections.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/19015341
      14. Call Number :
        137209
      15. Serial :
        5713
      1. Author :
        Kozloff, K. M.; Quinti, L.; Patntirapong, S.; Hauschka, P. V.; Tung, C. H.; Weissleder, R.; Mahmood, U.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2009
      5. Publication :
        Bone
      6. Products :
      7. Volume :
        44
      8. Issue :
        N/A
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        OsteoSense, IVIS Animals; Animals, Newborn; Bone Development; Bone Resorption/enzymology; Calcification, Physiologic; Cathepsin K; Cathepsins/genetics/*metabolism; Cell Survival; Cells, Cultured; Cryoultramicrotomy; Female; Femur/pathology; Fluorescence; Humans; Mice; Mice, Inbred BALB C; *Molecular Probe Techniques; Molecular Probes/metabolism; Osteoclasts/cytology/*enzymology; Ovariectomy; RNA, Messenger/genetics/metabolism; Up-Regulation
      12. Abstract :
        Osteoclasts degrade bone matrix by demineralization followed by degradation of type I collagen through secretion of the cysteine protease, cathepsin K. Current imaging modalities are insufficient for sensitive observation of osteoclast activity, and in vivo live imaging of osteoclast resorption of bone has yet to be demonstrated. Here, we describe a near-infrared fluorescence reporter probe whose activation by cathepsin K is shown in live osteoclast cells and in mouse models of development and osteoclast upregulation. Cathepsin K probe activity was monitored in live osteoclast cultures and correlates with cathepsin K gene expression. In ovariectomized mice, cathepsin K probe upregulation precedes detection of bone loss by micro-computed tomography. These results are the first to demonstrate non-invasive visualization of bone degrading enzymes in models of accelerated bone loss, and may provide a means for early diagnosis of upregulated resorption and rapid feedback on efficacy of treatment protocols prior to significant loss of bone in the patient.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/19007918
      14. Call Number :
        PKI @ kd.modi @ 1
      15. Serial :
        10466
      1. Author :
        Wallis de Vries, B. M.; van Dam, G. M.; Tio, R. A.; Hillebrands, J. L.; Slart, R. H.; Zeebregts, C. J.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2008
      5. Publication :
        J Vasc Surg
      6. Products :
      7. Volume :
        48
      8. Issue :
        N/A
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        MMPSense, IVIS, Atherosclerosis/complications/*diagnosis; Carotid Stenosis/*diagnosis/etiology; Diagnostic Imaging/*methods; Humans; Reproducibility of Results
      12. Abstract :
        BACKGROUND: There is increasing evidence that plaque vulnerability, rather than the degree of stenosis, is important in predicting the occurrence of subsequent cerebral ischemic events in patients with carotid artery stenosis. The many imaging modalities currently available have different properties with regard to the visualization of the extent of vulnerability in carotid plaque formation. METHODS: Original published studies were identified using the MEDLINE database (January 1966 to March 2008). Manual cross-referencing was also performed. RESULTS: There is no single imaging modality that can produce definitive information about the state of vulnerability of an atherosclerotic plaque. Each has its own specific drawbacks, which may be the use of ionizing radiation or nephrotoxic contrast agents, an invasive character, low patient tolerability, or simply the paucity of information obtained on plaque vulnerability. Functional molecular imaging techniques such as positron emission tomography (PET), single photon emission-computed tomography (SPECT) and near infra-red spectroscopy (NIRS) do seem able accurately to visualize and even quantify features of plaque vulnerability and its pathophysiologic processes. Promising new techniques like near infra-red fluorescence imaging are being developed and may be beneficial in this field. CONCLUSION: There is a promising role for functional molecular imaging modalities like PET, SPECT, or NIRS related to improvement of selection criteria for carotid intervention, especially when combined with CT or MRI to add further anatomical details to molecular information. Further information will be needed to define whether and where this functional molecular imaging will fit into a clinical strategy.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/18804942
      14. Call Number :
        PKI @ kd.modi @ 6
      15. Serial :
        10464
      1. Author :
        G. Blum
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2008
      5. Publication :
        Current Opinion in Drug Discovery Development
      6. Products :
      7. Volume :
        10
      8. Issue :
        2
      9. Page Numbers :
        N/A
      10. Research Area :
        Biology; Cancer
      11. Keywords :
        Proteases; pathology; biological markers; fluorescence imaging reagents; in vivo imaging; fluorescence molecular tomography; FMT
      12. Abstract :
        Proteases play pivotal roles in the normal function of cells. In addition, the expression and activity of proteases are significantly upregulated in several pathologies, including cancer, arthritis and atherosclerosis, and hence they can be considered to be biological markers for these pathologies. The hydrolyzing activity of proteases has been used to generate a variety of fluorescent imaging reagents, the design and utility of which are reviewed here. The use of imaging reagents to visualize protease activity allows for improved detection of various pathologies as well as the ability to monitor the efficacy of therapies in vivo and provide molecular information regarding the nature of the pathology.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/18729022
      14. Call Number :
        PKI @ sarah.piper @
      15. Serial :
        4475
      1. Author :
        Pozo, J. L. del; Rouse, M. S.; Mandrekar, J. N.; Sampedro, M. F.; Steckelberg, J. M.; Patel, R.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2009
      5. Publication :
        Antimicrobial Agents and Chemotherapy
      6. Products :
      7. Volume :
        53
      8. Issue :
        N/A
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        IVIS, Xenogen, Xen30, Xen5, Xen41
      12. Abstract :
        Bacterial biofilms are resistant to conventional antimicrobial agents. Prior in vitro studies have shown that electrical current (EC) enhances the activities of aminoglycosides, quinolones, and oxytetracycline against Pseudomonas aeruginosa, Klebsiella pneumoniae, Staphylococcus epidermidis, Escherichia coli, and Streptococcus gordonii. This phenomenon, known as the bioelectric effect, has been only partially defined. The purpose of this work was to study the in vitro bioelectric effect on the activities of 11 antimicrobial agents representing a variety of different classes against P. aeruginosa, methicillin-resistant Staphylococcus aureus (MRSA), and S. epidermidis. An eight-channel current generator/controller and eight chambers delivering a continuous flow of fresh medium with or without antimicrobial agents and/or EC to biofilm-coated coupons were used. No significant decreases in the numbers of log10 CFU/cm2 were seen after exposure to antimicrobial agents alone, with the exception of a 4.57-log-unit reduction for S. epidermidis and trimethoprim-sulfamethoxazole. We detected a statistically significant bioelectric effect when vancomycin plus 2,000 microamperes EC were used against MRSA biofilms (P = 0.04) and when daptomycin and erythromycin were used in combination with 200 or 2,000 microamperes EC against S. epidermidis biofilms (P = 0.02 and 0.0004, respectively). The results of these experiments indicate that the enhancement of the activity of antimicrobial agents against biofilm organisms by EC is not a generalizable phenomenon across microorganisms and antimicrobial agents.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/18725436
      14. Call Number :
        137347
      15. Serial :
        5991
      1. Author :
        Shan, Liang; Wang, Songping; Korotcov, Alexandru; Sridhar, Rajagopalan; Wang, Paul C
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2008
      5. Publication :
        Ethnicity & disease
      6. Products :
      7. Volume :
        18
      8. Issue :
        2 Suppl 2
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        Animals; Bioware; Breast Neoplasms; Disease Models, Animal; Humans; Luciferases; Luminescent Measurements; Lung Neoplasms; Mammary Neoplasms, Animal; MDA-MB-231-D3H1 cells; Mice; Mice, Nude; Tumor Cells, Cultured
      12. Abstract :
        INTRODUCTION Convenient animal models are needed to study the progression and treatment of human tumors in vivo. Luciferase-based bioluminescent imaging (BLI) enables researchers to monitor tumors noninvasively and is sensitive to subtle changes in tumors. METHODS Three human breast cancer models in nude mice were established by using luciferase-expressing MDA-MB-231-luc cells. They were subcutaneous xenografts (n = 8), mammary gland xenografts (n = 5), and lung metastases (n = 3). The tumors were imaged in live mice by using a highly sensitive BLI system. The relationship between the intensity of bioluminescence from the tumor was analyzed with respect to tumor volume. Bioluminescent signals from lung metastases were studied to determine the threshold of detectability. RESULTS Tumors growing in the mice's backs and mammary gland fat pads were imaged dynamically after administration of D-luciferin. The bioluminescent intensity from the tumors gradually increased and then decreased in a one-hour span. The time to reach maximum signal intensity differed significantly among tumors and was independent of tumor volume and unrelated to maximum signal intensity. A significant correlation was observed between tumor volume and maximum signal intensity in tumors from both sites. Lung metastatic lesions of .3-.5 mm in diameter were clearly detectable through the entire animal imaging process. CONCLUSION The animal models established with luciferase-expressing cancer cells in combination with BLI provide a system for rapid, noninvasive, and quantitative analysis of tumor biomass and metastasis. This biosystem simplifies in vivo monitoring of tumors and will be useful for noninvasive investigation of tumor growth and response to therapy.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/18646323
      14. Call Number :
        PKI @ catherine.lautenschlager @
      15. Serial :
        8991
Back to Search
Select All  |  Deselect All