1. Resources
  2. Citations Library

Citation Details

You are viewing citation details. You can save or export citation(s) below, access an article, or start a new search.

11–20 of 499 records found matching your query:
Back to Search
Select All  |  Deselect All

Headers act as filters

  •  
  • Records
      1. Author :
        Echchannaoui, H.; Frei, K.; Schnell, C.; Leib, S. L.; Zimmerli, W.; Landmann, R.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2002
      5. Publication :
        Journal of Infectious Diseases
      6. Products :
      7. Volume :
        186
      8. Issue :
        N/A
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        Animals, Ceftriaxone/therapeutic use, Cephalosporins/therapeutic use, Disease Models, Animal, Disease Susceptibility, Drosophila Proteins, Inflammation/genetics/immunology/microbiology/pathology, Listeria Infections/genetics/immunology, Listeria monocytogenes/genetics/immunology, Membrane Glycoproteins/ deficiency/genetics, Meningitis, Bacterial/ genetics/ immunology/microbiology/pathology, Mice, Mice, Inbred C57BL, Mice, Knockout, Pneumococcal Infections/genetics/immunology/microbiology/pathology, Receptors, Cell Surface/ deficiency/genetics, Streptococcus pneumoniae/ immunology, Time Factors, Toll-Like Receptor 2, Toll-Like Receptors IVIS, Xenogen, Xen10
      12. Abstract :
        Toll-like receptor-2 (TLR2) mediates host responses to gram-positive bacterial wall components. TLR2 function was investigated in a murine Streptococcus pneumoniae meningitis model in wild-type (wt) and TLR2-deficient (TLR2(-/-)) mice. TLR2(-/-) mice showed earlier time of death than wt mice (P<.02). Plasma interleukin-6 levels and bacterial numbers in blood and peripheral organs were similar for both strains. With ceftriaxone therapy, none of the wt but 27% of the TLR2(-/-) mice died (P<.04). Beyond 3 hours after infection, TLR2(-/-) mice had higher bacterial loads in brain than did wt mice, as assessed with luciferase-tagged S. pneumoniae by means of a Xenogen-CCD (charge-coupled device) camera. After 24 h, tumor necrosis factor activity was higher in cerebrospinal fluid of TLR2(-/-) than wt mice (P<.05) and was related to increased blood-brain barrier permeability (Evans blue staining, P<.02). In conclusion, the lack of TLR2 was associated with earlier death from meningitis, which was not due to sepsis but to reduced brain bacterial clearing, followed by increased intrathecal inflammation.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/12198614
      14. Call Number :
        137638
      15. Serial :
        7950
      1. Author :
        Engelsman, A. F.; Mei, H. C. van der; Francis, K. P.; Busscher, H. J.; Ploeg, R. J.; Dam, G. M. van
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2009
      5. Publication :
        J Biomed Mater Res B Appl Biomater
      6. Products :
      7. Volume :
        88
      8. Issue :
        N/A
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        Bioware; IVIS, Xenogen; Xen29
      12. Abstract :
        Infection is the main cause of biomaterials-related failure. A simple technique to test in-vivo new antimicrobial and/or nonadhesive implant coatings is unavailable. Current in vitro methods for studying bacterial adhesion and growth on biomaterial surfaces lack the influence of the host immune system. Most in vivo methods to study biomaterials-related infections routinely involve implant-removal, preventing comprehensive longitudinal monitoring. In vivo imaging circumvents these drawbacks and is based on the use of noninvasive optical imaging of bioluminescent bacteria. Staphylococcus aureus Xen29 is genetically modified to be stably bioluminescent, by the introduction of a modified full lux operon onto its chromosome. Surgical meshes with adhering S. aureus Xen29 were implanted in mice and bacterial growth and spread into the surrounding tissue was monitored longitudinally from bioluminescence with a highly sensitive CCD camera. Distinct spatiotemporal bioluminescence patterns, extending beyond the mesh area into surrounding tissues were observed. After 10 days, the number of living organisms isolated from explanted meshes was found to correlate with bioluminescence prior to sacrifice of the animals. Therefore, it is concluded that in vivo imaging using bioluminescent bacteria is ideally suited to study antimicrobial coatings taking into account the host immune system. In addition, longitudinal monitoring of infection in one animal will significantly reduce the number of experiments and animals.
      13. URL :
        http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=18618733
      14. Call Number :
        137698
      15. Serial :
        7462
      1. Author :
        Hardy, J.; Francis, K. P.; DeBoer, M.; Chu, P.; Gibbs, K.; Contag, C. H.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2004
      5. Publication :
        Science
      6. Products :
      7. Volume :
        303
      8. Issue :
        N/A
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        animal cell, animal model, article, bacterial colonization, bacterial growth, bacterial virulence, bioluminescence, cell culture, controlled study, extracellular space, gallbladder, in vivo study, Listeria monocytogenes, mouse, nonhuman, priority journal IVIS, Xenogen, Xen32
      12. Abstract :
        The bacterium Listeria monocytogenes can cause a life-threatening systemic illness in humans. Despite decades of progress in animal models of listeriosis, much remains unknown about the processes of infection and colonization. Here, we report that L. monocytogenes can replicate in the murine gall bladder and provide evidence that its replication there is extracellular and intraluminal. In vivo bioluminescence imaging was employed to determine the location of the infection over time in live animals, revealing strong signals from the gall bladder over a period of several days, in diseased as well as asymptomatic animals. The data suggest that L. monocytogenes may be carried in the human gall bladder.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/14764883
      14. Call Number :
        138442
      15. Serial :
        6154
      1. Author :
        Jenkins, D. E.; Oei, Y.; Hornig, Y. S.; Yu, S. F.; Dusich, J.; Purchio, T.; Contag, P. R.
      2. Title :
        Bioluminescent imaging (BLI) to improve and refine traditional murine models of tumor growth and metastasis
      3. Type :
        Journal Article
      4. Year :
        2003
      5. Publication :
        Clinical and Experimental Metastasis
      6. Products :
      7. Volume :
        20
      8. Issue :
        N/A
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        A549-luc-C8 cells; Animals, Cell Line, Tumor, Colonic Neoplasms/pathology, Fluorouracil/therapeutic use, Humans, Image Interpretation, Computer-Assisted, Longitudinal Studies, Luciferases/diagnostic use, Luminescent Measurements, Lung Neoplasms/ secondary, Lymphatic Metastasis, Male, Mice, Mice, SCID, Mitomycin/therapeutic use, Models, Biological, Neoplasm Transplantation, Prostatic Neoplasms/drug therapy/ pathology IVIS, Xenogen
      12. Abstract :
        Bioluminescent imaging (BLI) permits sensitive in vivo detection and quantification of cells specifically engineered to emit visible light. Three stable human tumor cell lines engineered to express luciferase were assessed for their tumorigenicity in subcutaneous, intravenous and spontaneous metastasis models. Bioluminescent PC-3M-luc-C6 human prostate cancer cells were implanted subcutaneously into SCID-beige mice and were monitored for tumor growth and response to 5-FU and mitomycin C treatments. Progressive tumor development and inhibition/regression following drug treatment were observed and quantified in vivo using BLI. Imaging data correlated to standard external caliper measurements of tumor volume, but bioluminescent data permitted earlier detection of tumor growth. In a lung colonization model, bioluminescent A549-luc-C8 human lung cancer cells were injected intravenously and lung metastases were monitored in vivo by whole animal imaging. Anesthetized mice were imaged weekly allowing a temporal assessment of in vivo lung tumor growth. This longitudinal study design permitted an accurate, real-time evaluation of tumor burden in the same animals over time. End-point bioluminescence measured in vivo correlated to total lung weight at necropsy. For a spontaneous metastatic tumor model, bioluminescent HT-29-luc-D6 human colon cancer cells implanted subcutaneously produced metastases to lung and lymph nodes in SCID-beige mice. Both primary tumors and micrometastases were detected by BLI in vivo. Ex vivo imaging of excised lung lobes and lymph nodes confirmed the in vivo signals and indicated a slightly higher frequency of metastasis in some mice. Levels of bioluminescence from in vivo and ex vivo images corresponded to the frequency and size of metastatic lesions in lungs and lymph nodes as subsequently confirmed by histology. In summary, BLI provided rapid, non-invasive monitoring of tumor growth and regression in animals. Its application to traditional oncology animal models offers quantitative and sensitive analysis of tumor growth and metastasis. The ability to temporally assess tumor development and responses to drug therapies in vivo also improves upon current standard animal models that are based on single end point data.
      13. URL :
        N/A
      14. Call Number :
        139189
      15. Serial :
        5565
      1. Author :
        Kadurugamuwa, J. L.; Francis, K. P.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2008
      5. Publication :
        Methods in Molecular Biology
      6. Products :
      7. Volume :
        431
      8. Issue :
        N/A
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        Bioware, Xen29, Animals, Bacteria/chemistry/ genetics, Bacterial Infections/diagnosis/ microbiology, Biofilms/ growth & development, Diagnostic Imaging/methods, Luminescent Measurements/ methods IVIS, Xenogen, Xen5, Xen44
      12. Abstract :
        Whole body biophotonic imaging (BPI) is a technique that has contributed significantly to the way researchers study bacterial pathogens and develop pre-clinical treatments to combat their ensuing infections in vivo. Not only does this approach allow disease profiles and drug efficacy studies to be conducted non-destructively in live animals over the entire course of the disease, but in many cases, it enables investigators to observe disease profiles that could otherwise easily be missed using conventional methodologies. The principles of this technique are that bacterial pathogens engineered to express bioluminescence (visible light) can be readily monitored from outside of the living animal using specialized low-light imaging equipment, enabling their movement, expansion and treatment to be seen completely non-invasively. Moreover, because the same group of animals can be imaged at each time-point throughout the study, the overall number of animals used is dramatically reduced, saving lives, time, and money. Also, as each animal acts as its own control over time, the issues associated with animal-to-animal variation are circumvented, thus improving the quality of the biostatistical data generated. The ability to monitor infections in vivo in a longitudinal fashion is especially appealing to assess chronic infections such as those involving implanted devices. Typically, bacteria grow as biofilms on these foreign bodies and are reputably difficult to monitor with conventional methods. Because of the non-destructive and non-invasive nature of BPI, the procedure can be performed repeatedly in the same animal, allowing the biofilm to be studied in situ without detachment or disturbance. This ability not only allows unique patterns of disease relapse to be seen following termination of antibiotic therapy but also in vivo resistance development during prolonged treatment, both of which are common occurrences with device-related infections. This chapter describes the bioluminescent engineering of both Gram-positive and Gram-negative bacteria and overviews their use in device-associated infections in several anatomical sites in a variety of animal models.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/18287760
      14. Call Number :
        139321
      15. Serial :
        5568
      1. Author :
        Kadurugamuwa, J. L.; Modi, K.; Coquoz, O.; Rice, B.; Smith, S.; Contag, P. R.; Purchio, T.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2005
      5. Publication :
        Infection and Immunity
      6. Products :
      7. Volume :
        73
      8. Issue :
        N/A
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        IVIS, Xenogen, Xen10
      12. Abstract :
        We developed a method for simultaneous in vivo biophotonic monitoring of pneumococcal meningitis and the accompanying neuronal injury in live transgenic mice. Streptococcus pneumoniae engineered for bioluminescence (lux) was used for direct visualization of disease progression and antibiotic treatment in a mouse model of meningitis. The host response was monitored in transgenic mice containing an inducible firefly luciferase (luc) reporter gene under transcriptional control of the mouse glial fibrillary acidic protein (GFAP) promoter. Based on the different spectra of light emission and substrate requirements for lux and luc, we were able to separately monitor the two reporters using a highly sensitive in vivo imaging system. The level of neuronal damage and recovery following antibiotic treatment was dependent on the time of treatment. This model has potential for simultaneous multiparameter monitoring and testing of therapies that target the pathogen or host response to prevent neuronal injury and recovery.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/16299273
      14. Call Number :
        139327
      15. Serial :
        7497
      1. Author :
        Kadurugamuwa, J. L.; Modi, K.; Yu, J.; Francis, K. P.; Orihuela, C.; Tuomanen, E.; Purchio, A. F.; Contag, P. R.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2005
      5. Publication :
        Mol Imaging
      6. Products :
      7. Volume :
        4
      8. Issue :
        N/A
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        Animals, Diagnostic Imaging, Disease Models, Animal, Female, Luminescent Measurements/methods, Meningitis, Pneumococcal/drug therapy/microbiology/ radiography, Mice, Mice, Inbred BALB C, Streptococcus pneumoniae/drug effects IVIS, Xenogen, Xen10
      12. Abstract :
        Noninvasive real-time in vivo bioluminescent imaging was used to assess the spread of Streptococcus pneumoniae throughout the spinal cord and brain during the acute stages of bacterial meningitis. A mouse model was established by lumbar (LP) or intracisternal (IC) injection of bioluminescent S. pneumoniae into the subarachnoid space. Bacteria replicated initially at the site of inoculation and spread progressively from the spinal cord to the brain or from the brain down to the cervical part of the spinal column and to the lower vertebral levels. After 24 hr, animals showed strong bioluminescent signals throughout the spinal canal, indicating acute meningitis of the intracranial and intraspinal meninges. A decline in bacterial cell viability, as judged by a reduction in the bioluminescent signal, was observed over time in animals treated with ceftriaxone, but not in untreated groups. Mice treated with the antibiotic survived infection, whereas all mice in untreated groups became moribund, first in the IC group then in the LP group. No untreated animal survived beyond 48 hr after induction of infection. Colony counts of infected cerebrospinal fluid (CSF) correlated positively with bioluminescent signals. This methodology is especially appealing because it allows detecting infected mice as early as 3 hr after inoculation, provide temporal, sequential, and spatial distribution of bacteria within the brain and spinal cord throughout the entire disease process and the rapid monitoring of treatment efficacy in a nondestructive manner. Moreover, it avoids the need to sacrifice the animals for CSF sampling and the potential manipulative damage that can occur with other conventional methods.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/16105511
      14. Call Number :
        139330
      15. Serial :
        7143
      1. Author :
        Kadurugamuwa, J. L.; Modi, K.; Yu, J.; Francis, K. P.; Purchio, T.; Contag, P. R.
      2. Title :
      3. Type :
        Journal Article
      4. Year :
        2005
      5. Publication :
        Infection and Immunity
      6. Products :
      7. Volume :
        73
      8. Issue :
        N/A
      9. Page Numbers :
        N/A
      10. Research Area :
        N/A
      11. Keywords :
        Animals, Diagnostic Imaging/ methods, Female, Mice, Microscopy, Electron, Scanning, Photons, Proteus Infections/ diagnosis, Proteus mirabilis/drug effects/isolation & purification, Pseudomonas Infections/ diagnosis, Pseudomonas aeruginosa/drug effects/isolation & purification, Urinary Catheterization/ adverse effects, Urinary Tract Infections/ diagnosis IVIS, Xenogen, Xen5, Xen44
      12. Abstract :
        Urinary tract infections (UTIs) are among the most common bacterial infections acquired by humans, particularly in catheterized patients. A major problem with catheterization is the formation of bacterial biofilms on catheter material and the risk of developing persistent UTIs that are difficult to monitor and eradicate. To better understand the course of UTIs and allow more accurate studies of in vivo antibiotic efficacy, we developed a catheter-based biofilm infection model with mice, using bioluminescently engineered bacteria. Two important urinary tract pathogens, Pseudomonas aeruginosa and Proteus mirabilis, were made bioluminescent by stable insertion of a complete lux operon. Segments of catheter material (precolonized or postimplant infected) with either pathogen were placed transurethrally in the lumen of the bladder by using a metal stylet without surgical manipulation. The bioluminescent strains were sufficiently bright to be readily monitored from the outside of infected animals, using a low-light optical imaging system, including the ability to trace the ascending pattern of light-emitting bacteria through ureters to the kidneys. Placement of the catheter in the bladder not only resulted in the development of strong cystitis that persisted significantly longer than in mice challenged with bacterial suspensions alone but also required prolonged antibiotic treatment to reduce the level of infection. Treatment of infected mice for 4 days with ciprofloxacin at 30 mg/kg of body weight twice a day cured cystitis and renal infection in noncatheterized mice. Similarly, ciprofloxacin reduced the bacterial burden to undetectable levels in catheterized mice but did not inhibit rebound of the infection upon cessation of antibiotic therapy. This methodology easily allows spatial information to be monitored sequentially throughout the entire disease process, including ascending UTI, treatment efficacy, and relapse, all without exogenous sampling, which is not possible with conventional methods.
      13. URL :
        http://www.ncbi.nlm.nih.gov/pubmed/15972473
      14. Call Number :
        139333
      15. Serial :
        7110
Back to Search
Select All  |  Deselect All